Kurt was professional, listened to my concerns and tackled the problem. Kurt also made suggestions for better performance in the future.
Luis had to climb into the attic and fish wire to the new themostat. Took the time to walk us through the setup of the wireless thermostat. Very professional and attentive to cleaning up after the job was completed.
Gas furnace replacement, Glen Mills, Pennsylvania, gas furnace installation Glenn Mills
Changed filters, cleared drains, checked delta t, checked electrical and wiring, inspected coils, checked pressures.
Noticed a compromised heat exchanger on this system, will have to be addressed before using the heat again. Also the fan motor is bd and Connor complete tune up. Need to order fan motor no return.
Performed QA on Amana Gas Furnace/AC system for the family/game room. Ran system in heating and cooling. Checked all programming and adjusted the cooling speed tap to F01. Set Heating stage delay to 10 minutes. Some small corrections were made to sealing the ductwork and installing the Service record. Completed checklist form in system. Installed an external Auto Reset Low Pressure Switch on the outdoor unit for the 2nd Floor System. Checked pressure switch connections with soap bubbles to make sure there were no leaks. Ran 2nd Floor system in cooling for over 20 minutes and measured refrigerant pressures. Pressures held at 131/259 in 1st Stage Cooling. Homeowner had a lot of questions about the pressure switch and how it works and the warranty. I talked to her about the repair and what the original issue was. System operating to standards at this time. No follow up is needed.
Performed QA on ClimateMaster system for the 2nd Floor. Homeowner was having issues with the thermostats not being connected to the Honeywell App. Spoke with Honeywell and had to reset the Gateway and reconnected all four thermostats. Connected all thermostats and had homeowner change on the app to make sure they were responding. Reviewed installation of the new system. Completed checklist form in system. Homeowner is going to contact David Powell to get the estimate on the additional well piping. He said all systems have been working very well so he will continue to monitor. No additional follow up is needed.
Completed AC tune up for 3 ton American standardAC system 16x25x1 filter in good condition Inspected condition of both the indoor and outdoor coil Measured temperature split (67-46=21°Good) and static pressure Ensured drains were clear. Left estimate for wet switch which will shut equipment down if water is detected on floor near equipment. Verified operation of condensate pump. Inspected wiring, controls, electric motors and components. Discussed and left email estimates for surge protectors. Verified integrity of compressor motors using megaohmeter. Monitored R410A refrigerant pressures and diagnostics 108;230 10°SC (Outdoor temp67°F) Good System is operating well at this time.
Bill was so impressed with his savings from the first floor systems that he’s going to entertain doing it on the second floor system now even though it’s upstairs he pumped still works. Going to put together some options between the Geo and Air Force heat pumps and email over.
Created proposal and sent to customer for furnace replacement for 1st floor.
Performed six month quality check, checked media filter ok. Checked heat pump setup. Updated cool cloud software. Tested electric heat. Started heat heat. Balanced refrigerant charge add 1 lb 4 oz. R410AChecked operation and temperature drop across coil.
Performed cooling maintenance, checked air filter ok. Cleaned condensate drain and cleaned pump. Checked voltage, amperage and electrical connections, measured capacitor values. Started air conditioner, checked refrigerant charge. Checked operation and temperature drop across coil.
Performed cooling maintenance, checked air filter ok. Cleaned eztrap and drain. Checked voltage, amperage and electrical connections, measured capacitor values.started air conditioner, checked refrigerant charge. Checked operation and temperature drop across coil.
Performed cooling maintenance, checked air filter ok. Cleaned condensate drain and trap. Checked voltage, amperage and electrical connections, measured capacitor values. Started air conditioner, checked refrigerant charge. Checked operation and temperature drop across coil.
Homeowner described that during recent windstorm house lost power for 2 hours. He tried resetting breakers. Found blown 3 amp fuse at air handler control. Replaced fuse and tested system operation. Made call from heat from honeywell Prestige IAQ stat. Checked filter. Measured temperature rise. Checked electric heat amps. System is operating well at the time of this service. Encouraged homeowner to become a Heating and Cooling plan member. Explained benefits, discounts and details of plan membership; Emailed quote.
Performed QA on Amana Heat Pump system. Reviewed installation with homeowner. Completed checklist form in system. Tested system in heat pump and auxiliary heat mode. This install passed the QA inspection. Only item that was addressed was the snow legs underneath of the outdoor unit were not under the unit completely. Was able to adjust the snow legs and reposition under the unit.